Integration of an echocardiographic motion-management system into photon-based stereotactic arrhythmia radioablation planning

Cardiology

...

19 October, 2026

Phys Imaging Radiat Oncol. 2026 Sep 29;41:101096. doi: 10.1016/j.phro.2026.101096. eCollection 2026 Sep.

ABSTRACT

BACKGROUND AND PURPOSE: Cardiorespiratory ultrasound motion monitoring may enhance the precision of dose delivery for stereotactic arrhythmia radioablation (STAR) of ventricular tachycardia. This treatment planning study aimed to evaluate the feasibility of photon-based STAR planning in the presence of an ultrasound probe.

MATERIALS AND METHODS: For sixteen targets in fourteen patients, three treatment plans were retrospectively created and compared: a reference plan without an ultrasound probe and two plans in which the ultrasound probe was spared from the primary treatment beam (apical or parasternal probe positions). Descriptive and statistical analyses were performed for target/organ dose-volume and treatment beam metrics, conformity-indices and maximum probe exposure.

RESULTS: The ultrasound probe could be spared from the primary beam in all cases with D0.035 cm³ < 1 Gy (median 0.2 Gy with apical and 0.4 Gy with parasternal placement) with slightly elevated organ dose-volume metrics and no significant differences in target dose-volume metrics. The conformity-index (50 % isodose line) differed significantly for apical and parasternal probe position (median reference plan 4.0 vs. 5.0 and 4.5, respectively; p < 0.01). The parasternal position gave slightly superior results compared to the apical position (e.g., heart minus planning target volume V12.5 Gy 7.6 % [4.7-13.3] vs. 8.2 % [6.4-12.5]; left lung V10 Gy 3.4 % [1.0-4.5] vs. 4.2 % [1.6-6.8]), albeit in all plans dose guidance parameters remained within clinically acceptable limits.

CONCLUSIONS: The ultrasound probe could be spared from the primary beam without compromising photon-based STAR plan quality beyond clinically acceptable deviations. The results support further investigation of ultrasound-based STAR motion management.

PMID:42894649 | PMC:PMC13676723 | DOI:10.1016/j.phro.2026.101096

Read Full Article

Journal Source :

European Heart Journal

© 2026 Imedsource, All Rights Reserved

Sustain the Knowledge Stream!

For unrestricted access to content and a seamless experience,

Continue to Login

Don't have an account?

We’d love to get to know you better!

Complete your profile to help us deliver a more personalized experience.